1. The Water Supply (water fittings) Regulations 1999 lay down:
2. A rigid pipework hot water system has a working pressure of 4bar. At what pressure should the pipework be tested for soundness?
3. Guidance on the installation procedures for domestic hot water systems can be found in :
4. Which of the following appliances is most likely to offer the customer low pressure at a hot water outlet?
5. If hard water is allowed to be heated above 65 oC what could be the consequence in the system?
6. A customer has intermittent flow of hot water from their bath tap – what is the most likely cause of the problem?
7. To overcome a dead leg for a hot water draw-off point, what course of action could be taken?
8. Which one of the following heat sources is regarded as a renewable source of energy?
9. Under Building Regulations Part G, what is a new or replacement immersion heater required to have?
10. The connection for a secondary circulation system return should be made at what point in the hot water cylinder?
11. If a flow switch on a pumped shower does not work, what would be the result?
12. With reference to hot water system pipework components, a service valve can be fitted to a :
13. With reference to domestic hot water systems, secondary circulation pipework is installed :
14. Guidance on the installation procedures for domestic hot water systems can be found in :
15. Which of the following appliances is most likely to offer the customer low pressure at a hot water outlet?
16. If hard water is allowed to be heated above 650 oC, what could be the consequence in the system?
17. What is used at a basin outlet to prevent contamination of the water system?
18. What is the primary function of the open vent on a domestic hot water system?
19. Under Building Regulations Part G, what is a new or replacement immersion heater required to have?
20. The connection for a secondary circulation system return should be made at what point in the hot water cylinder?
21. If a flow switch on a pumped shower does not work, what would be the result?
22. Which statement refers to a instantaneous system ?
23. In a feed and expansion cistern what is the minimum distance that has to be left from the water level to the warning/overflow pipe ?
24. The vent/distribution pipe from the top of the cylinder is not allowed to be attached vertically. What is this to prevent ?
25. Where would you find the cylinder thermostat on a cylinder ?
26. What is the horizontal distance from the top of the hot water cylinder before the vent pipe goes vertically to the cistern ?
27. In a feed and expansion cistern you need to allow for expansion of the total capacity of the system. How much % do you need to allow for ?
28. When secondary return pipes are used what other component should be used to move the water around the system ?
29. With respect to direct hot water systems, the heat exchanger should be made from what ?
30. Which of the following should be done if a cylinder you are going to install does not have insulation ?
31. On what type of system is it permissible to use a cast iron heat exchanger ?
32. Which of the following is an advantage of an open vented system ?
33. A thermostat on a unvented cylinder should only allow a maximum temperature of what ?
34. Which of the following is an disadvantage of an open vented system ?
35. What would happen if the membrane in an expansion vessel failed ?
36. Which connection for a shower is made to the top of the cylinder which replaces the standard M.I?
37. Cylinder collapse could occur when 2 pipes are blocked and the water is drawn off or cooled down. Which pipes would be blocked for this to occur ?
38. How high should the open vent be above the water level on the cold water storage cistern If the system has a head height of 15.5m ?
39. A fuel burning appliance used to heat up stored hot water is known as what ?
40. What is the maximum length of the discharge pipework on a unvented cylinder ?