1. In a two pipe central heating system :
2. Which one of the following components allows the customer independent control of the hot water and central heating system?
3. The steps to take prior to temporarily decommissioning a central heating system so that an additional radiator can be installed would include :
4. which one of the following describes the purpose of backgroud heating ?
5. The main objective of installing a central heating system in a property is :
6. Which Building Regulation covers the energy efficiency requirements for central heating systems?
7. The type of copper commonly used in the installation of central heating systems within domestic properties is :
8. Identify one advantage of underfloor heating :
9. What is the main reason a 150mm gap is left between the floor and the bottom of the radiator ?
10. What would be the Delta T temperature between a system with a flow temperature of 600 oC, a return temperature of 400 oC, and an ambient air temperature of 200 oC ?
11. In which of the following situations is it important to insulate central heating pipework?
12. One advantage of installing a fully pumped central heating system is:
13. What is the size of pipe used in micro-bore heating systems
14. A zone valve in an S plan central heating system is designed to :
15. Which central heating system uses a manifold ?
16. Which of the following components could be fitted with a remote sensor?
17. A disadvantage of using a one pipe heating system is that :
18. Which of the following statements relates to a full gravity heating system ?
19. What is a disadvantage of a one pipe system ?
20. Which of the following relates to existing commercial properties ?
21. When the floor plan is grater than 150m² what must be used to control the hot water and central heating circuits ?
22. Which of the following is incorrect in relation to a three-port mid-position valve ?
23. Which of the following statements are true ?
24. What is the cistern called that supply’s the central hearting circuit ?
25. In the cistern that supply’s a central heating system how much expansion do you need to allow for?
26. Once you have allowed for expansion in the F&E cistern how much of an air gap must be maintained from the water level to the vent pipe ?
27. What would be fitted to the incoming supply on the F&E cistern ?
28. What is the maximum surface temperature for a radiator the NHS can have in its hospitals ?
29. Radiators convect heat using the fins on the back of the panel. How much heat is convected and how much is radiated from the radiator ?
30. On a mid position valve the A port would refer to :
31. What is a two port valve also known as ?
32. At what temperature would you expect the cylinder thermostat to be set at ?
33. Filling a fully indirect open vented central heating system would be carried out through :
34. What component would act as a safety device on a sealed system if the expansion vessel failed ?
35. What is a disadvantage of a one pipe system ?
36. A damaged pump on a central heating system has been renewed on a number of occasions. Which one of the following could be a possible cause of the damage ?
37. Which one of the following measures could be taken to prevent unwanted circulation in heating system pipework ?
38. The downstairs radiators in a heating system are failing to warm up, whilst the upstairs radiators and hot water syatem are only lukewarm. What is the most likely fault ?
39. During maintenance procedures, in addition to turning off the electrical supply to any electrically operated components at the consumer unit which one of the following safety actions should be taken ?
40. Wiring diagrams for the heating controls on a fully pumped system can be found in the :